Why Knowing Common Ergoline Errors Matters More Than You Think
Running a successful tanning salon involves far more than just offering clients a relaxing experience. It requires staying on top of operational details, especially when it comes to your equipment. Ergoline tanning beds are known for their quality and advanced features, but like any machine, they are susceptible to issues. That’s why understanding common Ergoline errors is not just helpful—it’s crucial.
Imagine losing revenue for hours or even days simply because of an issue that could have been prevented or quickly resolved. When you know what to look for and how to respond, you can minimize disruptions, maintain client satisfaction, and prevent small issues from turning into costly repairs.
Common Ergoline errors typically appear in the form of error codes or performance issues, and learning how to interpret and fix these not only boosts your confidence but also positions you as a professional in the eyes of your clients.
How Typical Common Ergoline Errors and Malfunctions Can Undermine Customer Trust
Picture this: a client walks in after a stressful day, looking forward to their 20-minute escape in your tanning bed. Everything is set—but the bed doesn’t start. You try to troubleshoot while the client waits awkwardly, losing faith by the second. These are the moments where your knowledge of common Ergoline errors can make all the difference.
Clients don’t expect you to be an engineer, but they do expect the equipment to work. If you can resolve the issue quickly or at least explain it clearly, it shows professionalism and reliability. On the flip side, repeated malfunctions or cancellations due to equipment issues may drive clients to competitors.
Understanding common Ergoline errors helps you:
•Maintain trust and professionalism
•Deliver consistent, seamless services
•Avoid last-minute cancellations
•Turn one-time visitors into regulars
People don’t just buy tanning sessions—they buy experiences. If you can keep the equipment running smoothly, you’re delivering on that promise every single time.
Business Impact: How Frequent Ergoline Malfunctions Affect Revenue
Every minute that a tanning bed is out of service due to a technical issue is a minute you’re losing potential income. Whether it’s a faulty fan, a sensor problem, or something as simple as a misaligned panel, common Ergoline errors can hit your bottom line hard if not handled promptly.
Let’s do a quick calculation: if your average tanning session is £15 and your bed is down for 5 hours due to an unresolved error, that’s potentially over £100 lost in one day—just from one bed. Multiply that by a week or a month, and you can see how downtime adds up quickly.
Fortunately, many common Ergoline errors are avoidable or easily fixed if you know what to do:
•Routine maintenance (cleaning filters, checking connections)
•Understanding error codes
•Keeping spare parts (like bulbs and fuses)
•Educating your staff on simple troubleshooting steps
Staying proactive saves you time, money, and frustration—and allows your salon to run like a well-oiled machine.
Prevention First: Maintenance That Keeps Errors Away
There’s an old saying: “An ounce of prevention is worth a pound of cure.” Nowhere is this more true than with Ergoline equipment. Preventing common Ergoline errors is often easier and cheaper than fixing them after something goes wrong.
Here’s a list of practical, routine tasks that will drastically reduce the risk of technical problems:
• Start each day by wiping down all surfaces to remove lotions, oils, and dust—this helps preserve both hygiene and equipment lifespan.
• At least once a week, take time to vacuum the air filters and vents to ensure proper airflow and prevent overheating.
• Every month, track the usage hours of your bulbs and schedule replacements before they start to dim or fail.
• Every few months, perform a thorough check of wiring, acrylic panels, and electrical connections for any signs of wear or damage.
• At least once a year, bring in a qualified technician for a full system inspection and professional servicing.
By creating a checklist and sticking to it, you’ll extend the life of your equipment and reduce the chances of running into common Ergoline errors that lead to downtime.
It’s not just about keeping the beds running—it’s about delivering consistent results to every client who walks through your door.
Common Errors and How to Fix Them: A Handy Table
Error Code | Solution |
E001 Condensation tank full (Fault display only possible with the original condensation tank) |
Please empty the condensation tank regularly to prevent it from overflowing and to ensure the tanning machine operates efficiently. |
E002 Condensation pump fault/Condensation water seepage E003 Air conditioning system (device cooling ) over pressure switch E004 Pressure controller +B24 air conditioning pressure exceeded E005 Climatronic temperature sensor (air conditioning system) E006 Temperature sensor: Body air E010 Temperature limiter facial tanner E011 Canopy temperature limiter E012 Base temperature limiter E013 Temperature sensor: Canopy outlet air E014 Temperature sensor: Supply air E015 Temperature sensor: Device cooling air circulation E016 Temperature sensor: Air conditioning condenser E017 Temperature sensor circulation air, air inlet E018 Temperature of UV low pressure lamps lower than ambient temperature E019 Temperature of UV low pressure lamps at least 30 °C higher than ambient temperature E020 Filter panel rear and middle canopy facial tanner (FT1 & FT2) E021 Filter panel front facial tanner |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any common ergoline errors and any technical issues and ensure your equipment operates at its best. |
E022 Filter panel facial tanner in side section E023 Filter panel facial tanner canopy and side E024 Filter panel facial tanner in canopy |
Ensure that the filter panels are properly positioned and securely seated in the machine. Correct placement is crucial for optimal performance and to prevent potential damage to the equipment. |
E025 Filter panel facial tanner rear, middle and front as well as side section E026 Filter panel facial tanner 5-12 E027 Filter panel rear facial tanner E028 Filter panel middle facial tanner E029 Time overrun monitoring the high pressure units E030 Panel switch canopy acrylic cover (for the Ergoline Avantgarde with decorative panel) |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E030 Vertical tanner: Safety switch on the 2 left doors | Check doors. |
E031 Wafer switch: Plexiglass bed base or well base | Verify that the plexiglass bed base and the well are securely locked in place. Proper locking ensures safe operation and prevents potential malfunctions. |
E031 Vertical tanner: Safety switch on the 2 right doors | Check doors. |
E032 Panel switch acrylic covers canopy/base (Ergoline Premium: shoulder tanner, tank, front panel) |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E034 Panel switch acrylic cover canopy/side section/base/shoulder tanner/base tank | Ensure that the acrylic covers for the canopy, side section, base, shoulder tanner, and the tank are properly closed and securely locked. |
E035 Panel switch acrylic cover canopy/side section/base/shoulder tanner | Ensure that the acrylic covers for the canopy, side section, base, shoulder tanner, and the tank are properly closed and securely locked. |
E036 Panel switch acrylic cover base or base tank E037 Panel switch acrylic cover canopy/side section Check whether the acrylic cover canopy/side section are correctly closed/locked. |
Ensure that the tank is properly secured and locked. |
E038 Safety switch base and tank | Ensure that the tank and base is properly secured and locked. |
E039 Safety switch shoulder tanner E040 Air flow switch does not switch on with the fan running E041 Air flow switch does not switch off 1 minute after switching off of the fan E042 Warning, raising of the minimum speed of the main fan by 10 % E050 Safety switch: Front panel E051 Safety switch: Rear panel E052 Fault: Opening mechanism on the reflector arm (end position not reached within 45 seconds) E053 Safety switch UV high pressure lamps in the head area E054 Safety switch UV high pressure lamps in the foot area E055 Fault (temperature limiter) Facial tanner 1 front E056 Fault (temperature limiter) Facial tanner 2 rear E057 Fault (temperature limiter) Facial tanner front E058 Fault (temperature limiter) Facial tanner middle E059 Fault (temperature limiter) Facial tanner rear E060 Fault (temperature limiter) Facial tanner side section E061 Panel switch canopy acrylic cover, decorative trim panel or temperature limiter E062 Panel switch acrylic cover base/side section E063 Panel switch acrylic cover side section has triggered E064 Panel switch decorative trim panel has triggered E065 Panel switch canopy acrylic cover has triggered E066 Fault acrylic glass panel canopy and/or temperature fuse E070 Fault (temperature limiter) High pressure unit 1 * E071 Fault (temperature limiter) High pressure unit 2 * E072 Fault (temperature limiter) High pressure unit 3 * E073 Fault (temperature limiter) High pressure unit 4 * E074 Fault (temperature limiter) High pressure unit 5 * E075 Fault (temperature limiter) High pressure unit 6 * E076 Fault (temperature limiter) High pressure unit 7 * |
These are the most common ergoline errors. Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E077 Fault (temperature limiter) High pressure unit 8 * | |
E078 Fault (temperature limiter) High pressure unit 9 * | |
E079 Fault (temperature limiter) High pressure unit 10 * | |
E080 Fault (temperature limiter) High pressure unit 11 * E081 Fault (temperature limiter) High pressure unit 12 * E082 Fault (temperature limiter) High pressure unit 13 * E083 Fault (temperature limiter) High pressure unit 14 * E084 Fault (temperature limiter) High pressure unit 15 * E085 Fault (temperature limiter) High pressure unit 16 * |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E086 Monitor switched off by overheating protection | Let the monitor cool down for about 2 hours before restarting the MULTIVISION box. |
E090 Exceeding of the emergency shut-down time E091 Equipment bus fault E092 Wiring or voltage fault in the safety circuits E095 Auxiliary controller E097 Voltage error 5V electronics E098 Voltage error 12V electronics E099 Voltage error 24V electronics E100 Exceeding of the emergency shut-down time E101 Equipment bus fault E102 Wiring or voltage fault in the safety circuits |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E103 Fault in the music unit CD-/Chip- or drive fault |
Verify that the CDs or chip are properly installed or in place. |
E104 Chip card incorrectly inserted, defective or of the incorrect type, expired | Ensure the chip card is properly positioned. Verify the remaining usage time of the UV lamps and the total operating hours. |
E105 Auxiliary controller E106 Heating controller E107 Controller facial tanner regulation E108 Speed control 1 E109 Speed control 2 E110 Ergoline / Sunangel / Beauty Angel Controller AQUA FRESH (AQUA SYSTEM) and AROMA Soltron Controller VITALIZER (AQUA SYSTEM) and AROMA E111 Audio amplifier E112 Channel selection E113 Real time clock E114 Parameter memory/device pass certificate E115 Electronic ballast controller E116 Controller high pressure units regulation E117 No data transfer between sunbed and MULTIVISION box |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E118 No data transfer between sunbed and MULTIVISION box | Ensure that the plug connections to the MULTIVISION are securely and correctly positioned. This is common ergoline error code for Ergoline Excellence 800 Multivision. |
E119 Display unit missing or not ready for operation | Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E120 Sensor missing or not ready for operation | Verify that the sensor is in place and properly linked to the base station. Confirm that the base station is receiving power. |
E121 Sensor must be calibrated | Adjust the sensor calibration as outlined in the instruction manual. |
E122 Sensor calibration failed, sensor defective/dirty/ | Inspect and clean the sensor window thoroughly. Reinstall the sensor into the base station and repeat the procedure if needed. Afterward, recalibrate the sensor following the guidelines in the sunbed instruction manual. Ensure the correct calibration surface is used and confirm that it is free from dirt or debris. |
E123 Plausibility test fails (sensor defective/dirty, base station defective/dirty) | Inspect and clean both the sensor window and the base station. Properly reinstall the sensor into the base station, ensuring it is securely positioned. Repeat this process as needed. If the plausibility test fails, calibrate the sensor according to the instructions in the sunbed manual. |
E124 Sensor faulty E125 Internal sensor error |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E126 One or more mains power supply phases are missing | Check the main fuse. |
E128 Tanning interrupted because of low voltage | Confirm the error code and restart the device. |
E130 Controller assembled wrongly E131 Data communication with auxiliary controller faulty E132 Start-up inspection of UV sources faulty E133 Switch function auxiliary controller rotation speed control E134 Rotation speed control fuse faulty E135 Rotation speed control power supply faulty E140 Main contactor does not switch on E141 Main contactor does not switch off E142 Switch cycle of main contactor faulty E143 Coin box inputs different E150 Fault in the high pressure units (1-3) in series [A] (filter panels, temperature limiter) ** E151 Fault in the high pressure units (4-6) in series [A] (filter panels, temperature limiter) ** E152 Fault in the high pressure units (7-9) in series [B] (filter panels, temperature limiter) ** E153 Fault in the high pressure units (10-12) in series [B] (filter panels, temperature limiter) ** E154 Fault in the high pressure units (13-15) in series [C] (filter panels, temperature limiter) ** E155 Fault in the high pressure units (16-18) in series [C] (filter panels, temperature limiter) ** E156 Fault in the high pressure units (19-21) in series [D] (filter panels, temperature limiter) ** E157 Fault in the high pressure units (22-24) in series [D] (filter panels, temperature limiter) ** E158 Fault in the high pressure units (25-27) in series [E] (filter panels, temperature limiter) ** |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E159 Fault in the high pressure units (28-30) in series [E] (filter panels, temperature limiter) ** |
|
E160 Panel switch of the acrylic cover (1-6) in series [A] ** | |
E161 Panel switch of the acrylic cover (7-12) in series [B] ** | |
E162 Panel switch of the acrylic cover (13-18) in series [C] ** E163 Panel switch of the acrylic cover (19-24) in series [D] ** E164 Panel switch of the acrylic cover (25-30) in series [E] ** E165 Fault in the high pressure units (1-3) (filter panels, temperature limiter), Panel switch of the acrylic cover *** E166 Fault in the high pressure units (5-7) (filter panels, temperature limiter), Panel switch of the acrylic cover *** E167 Fault in the high pressure unit (4) (filter panels, temperature limiter) *** E168 Fault in the high pressure unit (8) (filter panels, temperature limiter) *** E170 No voltage to the fan inputs on the control board E190 Missing languages in control unit E191 Missing languages in audio controller E192 Timer mode active E199 Fatal error E200 Fault with the fan on the electronics mount E201 Faulty program |
Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
E202 Error during software update | Repeat the update process. |
E203 Faulty Voice Guide | Repeat the update process. |
E204 Operator identification missing | Contact us for professional service and support! Our highly skilled engineers are ready to assist you with any technical issues and ensure your equipment operates at its best. |
If you’d like to explore more about how Ergoline equipment functions or check official product specifications and documentation, visit the official Ergoline website. There, you’ll find valuable resources that complement this guide and help you stay up-to-date with the latest developments in sunbed technology.
Know When It’s Time to Call a Pro
Even if you’re well-versed in common Ergoline errors, it’s important to recognize when an issue is beyond your scope. Trying to fix a complex fault without the right knowledge or tools can make things worse—or even pose safety risks.
Here are signs that you should call a professional technician:
•Repeated or recurring errors that don’t go away
•Smell of burning or visible smoke
•Error codes related to power supply or voltage
•Problems involving the control panel or internal wiring
•Any situation involving physical damage to the bed
In these cases, reach out to a certified service provider. Not only will they fix the problem correctly, but they’ll also conduct a thorough inspection to ensure no underlying issues are missed.
👉 If you’re facing stubborn errors or need a professional diagnosis, don’t hesitate to contact us. Our experienced engineers at J Solutions Services Ltd are always ready to help.